Product Category menu

Amperometric Chlorine Dioxide Sensor MCD4.2

Product Detail Information

Chlorine dioxide Sensor CD4.2

Sensor for the measurement of chlorine dioxide, Membrane-covered, amperometric 2-electrode system.

Product description:
• Measurement: chlorine dioxide,
• Calibration: at the controller, am Controller, via analytical chlorine-dioxide determination by DPD-1 method
• Interferences: Cl2 is being registered with factor 0,03 of ist measured value, O3 is also registered
• pH range: 1 ... 11,
• Pressure range: 0 ... 1 bar, no pressure surges and/or fluctuations,
• Temperature range: 5 ... 45 °C,
• Integrated automatic temperature compensation,
• Response time: T90 approx. 15 s,
• Flow rate: approx. 30 l/h, low flow-dependence,
• Shaft length: 175 mm, 220 mm,
• Material: PVC-U, semipermeable membrane

Areas of application:
• Fresh water, surfactants must not be contained

Scope of supply:
• CD4.2: sensor, membrane cap, electrolyte